DMU-01

DMG MORI DMU 50 (3rd Generation) · Siemens SINUMERIK ONE · Bay 1 · Cell A · s/n DMU50-21183

Live machine view
Five-axis cycle
X/Y/Z, the swivelling B trunnion and the C rotary table follow live telemetry; the door opens when the machine stops. Drag to rotate, scroll to zoom.
Alarm
Effectiveness
OEE this shift
Night (22:00–06:00) · 133 of 164 min running
73%

Availability

81.4%

Performance

89.6%

Quality

100.0%

Current job
WO-24101
Mirror mount · VO-2075-A

Pieces

40 / 40

Cycle time

4m 12s

This piece

0s elapsed

Operator

Sandro Pereira

Tool

T11 · Ø8.5 drill

Tool life left

51%

Finishes

—

Losses
Downtime by reason
30.4 minutes lost this shift, biggest first.

Setup / first-off

11.7 min

Tool change

5.8 min

Breakdown

5.3 min

No material

3.3 min

Waiting QA

2.5 min

No operator

1.7 min

Quality
Pieces this shift
Ideal 324 s versus actual 362 s per piece.

Good

22

Scrap

0

Rework

0

OEE per hour · %

Queue
Jobs on this machine (3)
The job on the spindle and everything queued behind it, earliest due date first.

WO-24101

High

Aerodyn Systems · VO-2075-A OP30 · Invar 36 · setup 60 min

Paused

40/40 · due 06 Nov 23:43

WO-24105

Helvetica Medtech · AD-7742-B OP30 · Ti-6Al-4V · setup 31 min

Queued

0/50 · due 08 Nov 07:43

WO-24108

Sandvik Tooling · HM-2208-C OP20 · 316L stainless · setup 57 min

Queued

0/100 · due 08 Nov 10:43

Readings
Live telemetry
Polled every 5 seconds · spindle 10,642 h, service in 542 h

Spindle load

0 %

Spindle speed

0 rpm

Feed rate

0 mm/min

Spindle temp

21.4 °C

Coolant temp

19.6 °C

Coolant pressure

0 bar

Vibration

0 mm/s

Axis load B

0 %

Axis positions

X

0.0

Y

0.0

Z

0.0

B

0.0

C

0.0

Spindle history
Spindle load, speed and vibration

Spindle load · %

Spindle speed · rpm

Vibration · mm/s

Alarms
Alarms (4)

Spindle overload — feed hold triggered

Alarm 4073 · 11-05 10:41

Medium

Spindle overload — feed hold triggered

Alarm 4073 · 11-05 05:06

Medium

Air pressure below minimum

Alarm 8830 · 11-04 07:56

Medium

Air pressure below minimum

Alarm 8830 · 11-04 07:07

Medium