DMU-03

DMG MORI DMU 50 (3rd Generation) · Siemens SINUMERIK ONE · Bay 1 · Cell C · s/n DMU50-22211

Live machine view
Five-axis cycle
X/Y/Z, the swivelling B trunnion and the C rotary table follow live telemetry; the door opens when the machine stops. Drag to rotate, scroll to zoom.
Setup
Effectiveness
OEE this shift
Night (22:00–06:00) · 144 of 165 min running
65%

Availability

87.2%

Performance

74.7%

Quality

100.0%

Current job
WO-24117
Valve block · BH-9021-D

Pieces

7 / 20

Cycle time

6m 35s

This piece

0s elapsed

Operator

Sandro Pereira

Tool

T7 · Ø6 finishing end mill

Tool life left

59%

Finishes

—

Losses
Downtime by reason
21.0 minutes lost this shift, biggest first.

Setup / first-off

8.3 min

Tool change

4.6 min

No material

2.5 min

Breakdown

2.4 min

Waiting QA

1.9 min

No operator

1.2 min

Quality
Pieces this shift
Ideal 228 s versus actual 305 s per piece.

Good

28

Scrap

0

Rework

0

OEE per hour · %

Queue
Jobs on this machine (3)
The job on the spindle and everything queued behind it, earliest due date first.

WO-24117

Brunner Hydraulik · BH-9021-D OP30 · Al 6082 · setup 46 min

Late

7/20 · due 05 Nov 11:44

WO-24121

Sandvik Tooling · ST-3390-A OP20 · H13 tool steel · setup 35 min

Queued

0/20 · due 07 Nov 11:44

WO-24125

Hot

Helvetica Medtech · HM-2208-C OP10 · 316L stainless · setup 86 min

Queued

0/12 · due 08 Nov 11:44

Readings
Live telemetry
Polled every 5 seconds · spindle 14,433 h, service in 165 h

Spindle load

0 %

Spindle speed

0 rpm

Feed rate

0 mm/min

Spindle temp

21.2 °C

Coolant temp

20.3 °C

Coolant pressure

0 bar

Vibration

0 mm/s

Axis load B

0 %

Axis positions

X

0.0

Y

0.0

Z

0.0

B

0.0

C

0.0

Spindle history
Spindle load, speed and vibration

Spindle load · %

Spindle speed · rpm

Vibration · mm/s

Alarms
Alarms (8)

Door interlock opened during cycle

Alarm 6621 · 11-05 23:10

High

B axis drive temperature high

Alarm 1105 · 11-05 22:20

Medium

Tool life expired on T7, change required

Alarm 2019 · 11-05 21:58

Low

Tool life expired on T7, change required

Alarm 2019 · 11-04 22:24

High

C axis following error

Alarm 1188 · 11-04 13:29

Medium

Coolant level low in the tank

Alarm 7014 · 11-04 08:49

High

Coolant level low in the tank

Alarm 7014 · 11-04 08:02

High

Coolant level low in the tank

Alarm 7014 · 11-04 04:06

High